<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>HH-100 Thermo Shaker Incubator (Heating) &#8211; Lab suplies, Equipaments, chemicals, Instruments.</title>
	<atom:link href="https://eceratrading.com/product-tag/hh-100-thermo-shaker-incubator-heating/feed/" rel="self" type="application/rss+xml" />
	<link>https://eceratrading.com</link>
	<description>Eceratrading.com: Precision Solutions for Your Laboratory Needs!</description>
	<lastBuildDate>Thu, 27 Mar 2025 15:04:31 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.0.4</generator>

<image>
	<url>https://eceratrading.com/wp-content/uploads/2020/08/cropped-eceratrading.com-logo-32x32.png</url>
	<title>HH-100 Thermo Shaker Incubator (Heating) &#8211; Lab suplies, Equipaments, chemicals, Instruments.</title>
	<link>https://eceratrading.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>HH-100 Thermo Shaker Incubator (Heating)</title>
		<link>https://eceratrading.com/product/hh-100-thermo-shaker-incubator-heating/</link>
		
		<dc:creator><![CDATA[jose]]></dc:creator>
		<pubDate>Thu, 15 Apr 2021 19:48:45 +0000</pubDate>
				<guid isPermaLink="false">https://eceratrading.com/?post_type=product&#038;p=2647</guid>

					<description><![CDATA[<span class="text1">HH-100 Thermo Shaker Incubator (Heating)</span>
<h3>Product overview</h3>
<div class="d1">
<p class="text3 overflowell2">HH-100, controlled by DC brushless motor and microcomputer, perfectly combines the constant temperature and shaking, which greatly shortens the time of experiment operation and improves the efficiency. It is an ideal automation tool for sample incubation, catalysis, mixing and preservation. HH-100 also has multi-purpose functions such as heating and oscillation to meet different needs.</p>

</div>]]></description>
										<content:encoded><![CDATA[<div class="productsdetailmain pc">
<div class="productsmainbg">
<div class="productsdetailmainbox">
<div class="productsdetail-content pc">
<p><strong>Product Feature:</strong><strong> </strong></p>
<p>1. LCD display</p>
<p>2. Unique anti-vibration technology</p>
<p>3. Automatically resume operation according to the original setting program after the power is restored</p>
<p>4. Accurate shaking speed and small fluctuation</p>
<p>5. Timing, the training time can be set arbitrarily within 0-100 hours.</p>
<p>6. Various standard sample blocks for easy replacement</p>
<p>7. Temperature calibration and transient oscillation</p>
<p>8. Long life and free maintenance</p>
<p>9. Multiple safety protection, complying with CE safety standard</p>
<p><strong>The Basic Parameters:</strong></p>
<table width="584">
<tbody>
<tr class="firstRow">
<td width="234"><strong>Type</strong></p>
<p><strong>Parameter</strong></td>
<td width="180"><strong>HC-100 (Cooling)</strong></td>
<td width="170"><strong>HH-100 (Heating)</strong></td>
</tr>
<tr>
<td width="234">Temperature Range</td>
<td width="180">-10℃—100℃</td>
<td width="170">R.T.+5℃—100℃</td>
</tr>
<tr>
<td width="234">Temperature   Control Accuracy</td>
<td colspan="2" width="350">±0.3℃</td>
</tr>
<tr>
<td width="234">Temperature   Control Discrepancy @40℃</td>
<td colspan="2" width="350">±0.3℃</td>
</tr>
<tr>
<td width="234">Temperature   Control Discrepancy @100℃</td>
<td colspan="2" width="350">±0.3℃</td>
</tr>
<tr>
<td width="234">Temperature Display Accuracy</td>
<td colspan="2" width="350">0.1℃</td>
</tr>
<tr>
<td width="234">Speed</td>
<td width="180">200—1500 rpm</td>
<td width="170">200—2000 rpm</td>
</tr>
<tr>
<td width="234">Amplitude</td>
<td colspan="2" width="350">2 mm (Horizontal Rotation)</td>
</tr>
<tr>
<td width="234">Time</td>
<td colspan="2" width="350">0-99h59m</td>
</tr>
<tr>
<td width="234">Heating Time (25℃ to 100℃)</td>
<td colspan="2" width="350">&lt;15min</td>
</tr>
<tr>
<td width="234">Cooling Time</td>
<td width="180">≤25min (From R.T. to below 20 ℃) ((Temp≤30℃))</td>
<td width="170">/</td>
</tr>
<tr>
<td width="234">Cooling Speed</td>
<td width="180">≥7℃/min (From 100℃ down to 20℃)</p>
<p>≥1.2℃/min (From R.T. to below 20 ℃)</td>
<td width="170">/</td>
</tr>
<tr>
<td width="234">Power</td>
<td colspan="2" width="350">150W</td>
</tr>
<tr>
<td width="234">Dimension(L×W×H)   (mm)</td>
<td colspan="2" width="350">300×220×170</td>
</tr>
<tr>
<td width="234">Net Weight</td>
<td width="180">8.8 kg</td>
<td width="170">7.9 kg</td>
</tr>
<tr>
<td width="234">Insert Blocks</td>
<td colspan="2" width="350">Block Form</td>
</tr>
</tbody>
</table>
<p><strong>Three Methods of Mixing and Incubation:</strong></p>
<table width="568">
<tbody>
<tr class="firstRow">
<td width="215"><strong>Work Plate</strong></p>
<p><strong>(Mixing &amp; Shaking)</strong></td>
<td width="125"><strong>Centrifuge Tube Rack (Mixing &amp; Shaking)</strong></td>
<td width="164"><strong>Blocks (Heating, Incubation, Mixing   &amp; Shaking)</strong></td>
</tr>
<tr>
<td width="215">96-hole   PCR plat(with Skirt, Semi-skirt and No Skirt)</td>
<td width="125">0.2ml   PCR tube rack</p>
<p>PCR   tube strip rack</td>
<td rowspan="4" width="164">Insert Block: Block Form of HC-100/HH-100</td>
</tr>
<tr>
<td width="215">384-hole   PCR plat</td>
<td width="125">0.5ml Centrifuge   tube rack</td>
</tr>
<tr>
<td width="215">96/384   holes deep-well plates</td>
<td width="125">1.5ml/2.0ml Centrifuge   tube rack</td>
</tr>
<tr>
<td width="215">MTP Microplate/   Elisa Plate</td>
<td width="125">/</td>
</tr>
</tbody>
</table>
<p><strong>Insert Block:</strong></p>
<table width="608">
<tbody>
<tr class="firstRow">
<td width="96"><strong>Type</strong></td>
<td width="278"><strong>Tube Diameter/Quantity</strong></td>
<td width="100"><strong>Max. Temp.</strong></td>
<td width="134"><strong>Max. Speed</strong></td>
</tr>
<tr>
<td width="96">A1</td>
<td width="278">96×0.2ml Standard board</td>
<td width="100">100℃</td>
<td width="134">2000rpm</td>
</tr>
<tr>
<td width="96">A2</td>
<td width="278">54×0.5ml Centrifuge tube</td>
<td width="100">100℃</td>
<td width="134">2000rpm</td>
</tr>
<tr>
<td width="96">A3</td>
<td width="278">35×1.5ml Centrifuge tube</td>
<td width="100">100℃</td>
<td width="134">2000rpm</td>
</tr>
<tr>
<td width="96">A4</td>
<td width="278">35×2.0ml Centrifuge tube</td>
<td width="100">100℃</td>
<td width="134">2000rpm</td>
</tr>
<tr>
<td width="96">A5</td>
<td width="278">20×0.5ml+15×1.5ml Centrifuge tube</td>
<td width="100">100℃</td>
<td width="134">2000rpm</td>
</tr>
<tr>
<td width="96">A6</td>
<td width="278">24×φ12mm Tube</td>
<td width="100">100℃</td>
<td width="134">2000rpm</td>
</tr>
<tr>
<td width="96">A7</td>
<td width="278">32×0.2ml+25×1.5ml Centrifuge tube</td>
<td width="100">100℃</td>
<td width="134">2000rpm</td>
</tr>
<tr>
<td width="96">A8</td>
<td width="278">32×0.2ml+10×0.5ml+15×1.5ml Centrifuge tube</td>
<td width="100">100℃</td>
<td width="134">2000rpm</td>
</tr>
<tr>
<td width="96">A9</td>
<td width="278">103×67×30 (Water Bath Block)</td>
<td width="100">100℃</td>
<td width="134">2000rpm</td>
</tr>
<tr>
<td width="96">A10</td>
<td width="278">96×0.2ml Elisa Plate (Flat)</td>
<td width="100">100℃</td>
<td width="134">2000rpm</td>
</tr>
<tr>
<td width="96">A11</td>
<td width="278">24×5ml  Centrifuge   tube</td>
<td width="100">100℃</td>
<td width="134">2000rpm</td>
</tr>
<tr>
<td width="96">A12</td>
<td width="278">12×15ml Centrifuge tube</td>
<td width="100">100℃</td>
<td width="134">700rpm</td>
</tr>
<tr>
<td width="96">A13</td>
<td width="278">6×50ml Centrifuge tube</td>
<td width="100">100℃</td>
<td width="134">700rpm</td>
</tr>
<tr>
<td width="96">A14</td>
<td width="278">Customized</td>
<td width="100">100℃</td>
<td width="134">/</td>
</tr>
<tr>
<td width="96">MIX-A1</td>
<td width="278">96×0.2ml Centrifuge tube rack</td>
<td width="100">/</td>
<td width="134">2000rpm</td>
</tr>
<tr>
<td width="96">MIX-A2</td>
<td width="278">24×0.5ml Centrifuge tube rack</td>
<td width="100">/</td>
<td width="134">2000rpm</td>
</tr>
<tr>
<td width="96">MIX-A3</td>
<td width="278">24×1.5/2.0ml Centrifuge tube rack</td>
<td width="100">/</td>
<td width="134">/</td>
</tr>
</tbody>
</table>
<p><img fetchpriority="high" decoding="async" title="A1-A13.jpg" src="http://www.yooning.com/upload/image/20181012/15393252907604811.jpg" alt="A1-A13.jpg" width="646" height="448" /></p>
<p><img decoding="async" title="HX-A1.jpg" src="http://www.yooning.com/upload/image/20181012/15393253184187376.jpg" alt="HX-A1.jpg" width="584" height="211" /></p>
<p>&nbsp;</p>
</div>
</div>
</div>
</div>
<div id="form" class="pc">
<div class="form">
<div class="tubiao">
<div><img decoding="async" src="https://www.yooning.com/static/upload/image/20200414/1586859129209458.png" /></div>
</div>
</div>
</div>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
