<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>HC-100 Thermo Shaker Incubator (Cooling) &#8211; Lab suplies, Equipaments, chemicals, Instruments.</title>
	<atom:link href="https://eceratrading.com/product-tag/hc-100-thermo-shaker-incubator-cooling/feed/" rel="self" type="application/rss+xml" />
	<link>https://eceratrading.com</link>
	<description>Eceratrading.com: Precision Solutions for Your Laboratory Needs!</description>
	<lastBuildDate>Thu, 27 Mar 2025 15:04:30 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.0.4</generator>

<image>
	<url>https://eceratrading.com/wp-content/uploads/2020/08/cropped-eceratrading.com-logo-32x32.png</url>
	<title>HC-100 Thermo Shaker Incubator (Cooling) &#8211; Lab suplies, Equipaments, chemicals, Instruments.</title>
	<link>https://eceratrading.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>HC-100 Thermo Shaker Incubator (Cooling)</title>
		<link>https://eceratrading.com/product/hc-100-thermo-shaker-incubator-cooling/</link>
		
		<dc:creator><![CDATA[jose]]></dc:creator>
		<pubDate>Thu, 15 Apr 2021 23:55:03 +0000</pubDate>
				<guid isPermaLink="false">https://eceratrading.com/?post_type=product&#038;p=2650</guid>

					<description><![CDATA[<span class="text1">HC-100 Thermo Shaker Incubator (Cooling)</span>
<h3>Product overview</h3>
<div class="d1">
<p class="text3 overflowell2">HC-100, controlled by DC brushless motor and semiconductor refrigeration technology, perfectly combines cooling and heating and oscillation, which greatly shortens the time of experiment operation and improves the efficiency. It is an ideal automation tool for sample incubation, catalysis, mixing and preservation. HC-100 also has multi-purpose functions such as heating and oscillation to meet the needs of different users.</p>

</div>]]></description>
										<content:encoded><![CDATA[<div class="productsdetailmain pc">
<div class="productsmainbg">
<div class="productsdetailmainbox">
<div class="productsdetail-content pc">
<p><strong>Product Feature:</strong></p>
<p>1. Unique anti-vibration technology</p>
<p>2. Independently use thermostat, shaking and timing</p>
<p>3. Metal blocks for high temperature uniformity and easy replacement</p>
<p>4. Low noise, long life and free maintenance</p>
<p>5. LCD display; the temperature and the speed real-time display</p>
<p>6. Temperature calibration and transient shaking</p>
<p>7. Accurate shaking speed and small fluctuation</p>
<p>8. The program stops and an alarm is issued</p>
<p>9. Automatically resume operation to meet different requirement</p>
<p><strong>The Basic Parameters:</strong></p>
<table width="604">
<tbody>
<tr class="firstRow">
<td width="291"><strong>Type</strong></p>
<p><strong>    Parameter</strong></td>
<td colspan="2" width="170"><strong>HC-100 (Cooling)</strong></td>
<td width="143"><strong>HH-100</strong><strong>（</strong><strong>Heating</strong><strong>）</strong></td>
</tr>
<tr>
<td width="291">Temperature   Range</td>
<td colspan="2" width="170">-10℃—100℃</td>
<td width="143">R.T.+5℃—100℃</td>
</tr>
<tr>
<td width="291">Temperature   Control Accuracy</td>
<td colspan="3" width="313">±0.3℃</td>
</tr>
<tr>
<td width="291">Temperature   Control Discrepancy@40℃</td>
<td colspan="3" width="313">±0.3℃</td>
</tr>
<tr>
<td width="291">Temperature   Control Discrepancy@100℃</td>
<td colspan="3" width="313">±0.3℃</td>
</tr>
<tr>
<td width="291">Temperature   Display Accuracy</td>
<td colspan="3" width="313">0.1℃</td>
</tr>
<tr>
<td width="291">Speed</td>
<td colspan="2" width="170">200—1500 rpm</td>
<td width="143">200—2000 rpm</td>
</tr>
<tr>
<td width="291">Amplitude</td>
<td colspan="3" width="313">2mm (Horizontal Rotation)</td>
</tr>
<tr>
<td width="291">Time</td>
<td colspan="3" width="313">0-99h59min</td>
</tr>
<tr>
<td width="291">Heating Time   (25℃ to 100℃)</td>
<td colspan="3" width="313">&lt;15min</td>
</tr>
<tr>
<td width="291">Cooling Time</td>
<td colspan="2" width="170">≤25min (R.T. to below 20 ℃)(Ambient below 30℃)</td>
<td width="143">/</td>
</tr>
<tr>
<td width="291">Cooling Speed</td>
<td colspan="2" width="170">≥7℃/min (100℃ down to 20℃)</p>
<p>≥1.2℃/min (R.T. to below 20℃)</td>
<td width="143">/</td>
</tr>
<tr>
<td width="291">Power</td>
<td colspan="3" width="313">150W</td>
</tr>
<tr>
<td width="291">Dimension(L×W×H)</td>
<td colspan="3" width="313">300×220×170 mm</td>
</tr>
<tr>
<td width="291">Net Weight</td>
<td width="132">8.8 kg</td>
<td colspan="2" width="181">7.9 kg</td>
</tr>
<tr>
<td width="291">Insert Blocks</td>
<td colspan="3" width="313">Block Form</td>
</tr>
</tbody>
</table>
<p><strong>Three Methods of Mixing and Incubation:</strong></p>
<table width="607">
<tbody>
<tr class="firstRow">
<td width="213"><strong>Work Plate</strong></p>
<p><strong>(Mixing &amp; Shaking)</strong></td>
<td width="229"><strong>Centrifuge Tube Rack (Mixing &amp; Shaking)</strong></td>
<td width="165"><strong>Blocks (Heating, Incubation, Mixing   &amp; Shaking)</strong></td>
</tr>
<tr>
<td width="213">96-hole   PCR plat(with Skirt, Semi-skirt and No Skirt)</td>
<td width="229">0.2ml   PCR tube rack</p>
<p>PCR   tube strip rack</td>
<td rowspan="4" width="165">Insert Block: Block Form of HC-100/HH-100</td>
</tr>
<tr>
<td width="213">384-hole   PCR plat</td>
<td width="229">0.5ml Centrifuge   tube rack</td>
</tr>
<tr>
<td width="213">96/384   holes deep-well plates</td>
<td width="229">1.5ml/2.0ml Centrifuge   tube rack</td>
</tr>
<tr>
<td width="213">MTP Microplate/   Elisa Plate</td>
<td width="229">/</td>
</tr>
</tbody>
</table>
<p><strong>Insert Block:</strong></p>
<table width="608">
<tbody>
<tr class="firstRow">
<td valign="top" width="111"><strong>Type</strong></td>
<td width="246"><strong>Tube Diameter/Quantity</strong></td>
<td width="117"><strong>Max. Temp.</strong></td>
<td width="134"><strong>Max. Speed</strong></td>
</tr>
<tr>
<td width="111">A1</td>
<td width="246">96×0.2ml Standard board</td>
<td valign="top" width="117">100℃</td>
<td valign="top" width="134">1500rpm</td>
</tr>
<tr>
<td width="111">A2</td>
<td width="246">54×0.5ml Centrifuge tube</td>
<td valign="top" width="117">100℃</td>
<td valign="top" width="134">1500rpm</td>
</tr>
<tr>
<td width="111">A3</td>
<td width="246">35×1.5ml Centrifuge tube</td>
<td valign="top" width="117">100℃</td>
<td valign="top" width="134">1500rpm</td>
</tr>
<tr>
<td width="111">A4</td>
<td width="246">35×2.0ml Centrifuge tube</td>
<td valign="top" width="117">100℃</td>
<td valign="top" width="134">1500rpm</td>
</tr>
<tr>
<td width="111">A5</td>
<td width="246">20×0.5ml+15×1.5ml Centrifuge tube</td>
<td valign="top" width="117">100℃</td>
<td valign="top" width="134">1500rpm</td>
</tr>
<tr>
<td width="111">A6</td>
<td width="246">24×φ12mm Tube</td>
<td valign="top" width="117">100℃</td>
<td valign="top" width="134">1500rpm</td>
</tr>
<tr>
<td width="111">A7</td>
<td width="246">32×0.2ml+25×1.5ml Centrifuge tube</td>
<td valign="top" width="117">100℃</td>
<td valign="top" width="134">1500rpm</td>
</tr>
<tr>
<td width="111">A8</td>
<td width="246">32×0.2ml+10×0.5ml+15×1.5ml Centrifuge tube</td>
<td valign="top" width="117">100℃</td>
<td valign="top" width="134">1500rpm</td>
</tr>
<tr>
<td width="111">A9</td>
<td width="246">103×67×30 ( Water Bath Block )</td>
<td valign="top" width="117">100℃</td>
<td valign="top" width="134">1500rpm</td>
</tr>
<tr>
<td width="111">A10</td>
<td width="246">96×0.2ml Elisa Plate (Flat)</td>
<td valign="top" width="117">100℃</td>
<td valign="top" width="134">1500rpm</td>
</tr>
<tr>
<td width="111">A11</td>
<td width="246">24×5ml  Centrifuge tube</td>
<td valign="top" width="117">100℃</td>
<td valign="top" width="134">1500rpm</td>
</tr>
<tr>
<td width="111">A12</td>
<td width="246">12×15ml Centrifuge tube</td>
<td valign="top" width="117">  100℃</td>
<td valign="top" width="134">700rpm</td>
</tr>
<tr>
<td width="111">A13</td>
<td width="246">6×50ml Centrifuge tube</td>
<td valign="top" width="117">100℃</td>
<td valign="top" width="134">700rpm</td>
</tr>
<tr>
<td width="111">A14</td>
<td width="246">Customized</td>
<td valign="top" width="117">  100℃</td>
<td valign="top" width="134"></td>
</tr>
<tr>
<td valign="top" width="111">MIX-A1</td>
<td width="246">96×0.2ml Centrifuge tube racks</td>
<td valign="top" width="117">/</td>
<td valign="top" width="134">1500rpm</td>
</tr>
<tr>
<td valign="top" width="111">MIX-A2</td>
<td width="246">24×0.5ml Centrifuge tube racks</td>
<td valign="top" width="117">/</td>
<td valign="top" width="134">1500rpm</td>
</tr>
<tr>
<td valign="top" width="111">MIX-A3</td>
<td width="246">24×1.5/2.0ml Centrifuge tube racks</td>
<td valign="top" width="117">/</td>
<td valign="top" width="134">1500rpm</td>
</tr>
</tbody>
</table>
<p><img fetchpriority="high" decoding="async" title="A1-A13.jpg" src="http://www.yooning.com/upload/image/20181012/15393252907604811.jpg" alt="A1-A13.jpg" width="646" height="448" /></p>
<p><img decoding="async" title="HX-A1.jpg" src="http://www.yooning.com/upload/image/20181012/15393253184187376.jpg" alt="HX-A1.jpg" width="583" height="211" /></p>
<p>&nbsp;</p>
</div>
</div>
</div>
</div>
<div id="form" class="pc">
<div class="form">
<div class="tubiao"></div>
</div>
</div>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
