<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Sample Concentrator &#8211; Lab suplies, Equipaments, chemicals, Instruments.</title>
	<atom:link href="https://eceratrading.com/product-category/yooning/sample-concentrator/feed/" rel="self" type="application/rss+xml" />
	<link>https://eceratrading.com</link>
	<description>Eceratrading.com: Precision Solutions for Your Laboratory Needs!</description>
	<lastBuildDate>Thu, 27 Mar 2025 15:04:32 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.0.5</generator>

<image>
	<url>https://eceratrading.com/wp-content/uploads/2020/08/cropped-eceratrading.com-logo-32x32.png</url>
	<title>Sample Concentrator &#8211; Lab suplies, Equipaments, chemicals, Instruments.</title>
	<link>https://eceratrading.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>DC150-1B Visible Sample Concentrator</title>
		<link>https://eceratrading.com/product/dc150-1b-visible-sample-concentrator/</link>
		
		<dc:creator><![CDATA[jose]]></dc:creator>
		<pubDate>Thu, 29 Apr 2021 22:31:42 +0000</pubDate>
				<guid isPermaLink="false">https://eceratrading.com/?post_type=product&#038;p=2866</guid>

					<description><![CDATA[<span class="text1">DC150-1B Visible Sample Concentrator</span>
<h3>Product overview</h3>
&#160;

DC150-1B is a high-precision control instrument that combines microcomputer and PID. Working principle: the nitrogen can be blowed onto the surface of the heated samples and then set the heating temperature to achieve rapid concentration of a large number of samples.]]></description>
										<content:encoded><![CDATA[<p><strong>Product feature:</strong></p>
<p>1. The heater allows samples to be heated rapidly to the evaporation temperature, through the gas blow to the solution surface via needle at the same time, prompting rapid evaporation and concentration solution.</p>
<p>2. The gas chamber height can be adjusted</p>
<p>3. Each blow needle can be controlled independently; can be blown, separate flow regulation, no waste of gas.</p>
<p>4. The entire system can be arranged in the ventilation cabinet when process concentration of toxic solvents.</p>
<p>5. Built in over-temperature protection device, automatic fault detection and alarm function.</p>
<p>6. LED display, temperature and time diminishing display, the operation is simple and convenient.</p>
<p>&nbsp;</p>
<p><strong>The Basic Parameters:</strong></p>
<p>&nbsp;</p>
<table width="741">
<tbody>
<tr class="firstRow">
<td width="338"><strong>               Type</strong></p>
<p><strong>Parameter</strong></td>
<td width="255"><strong>DC150-1B</strong></td>
</tr>
<tr>
<td width="338">Temperature Range</td>
<td width="255">R.T.+5℃ ~150℃</td>
</tr>
<tr>
<td width="338">Heating Time(20-150 °C)</td>
<td width="255">≤30m</td>
</tr>
<tr>
<td width="338">Temperature Control Discrepancy @40 °C</td>
<td width="255">≤±0.3℃</td>
</tr>
<tr>
<td width="338">Temperature Control Discrepancy @100 °C</td>
<td width="255">≤±0.5℃</td>
</tr>
<tr>
<td width="338">Temperature Control Discrepancy @120 °C</td>
<td width="255">≤±1℃</td>
</tr>
<tr>
<td width="338">Blocks</td>
<td width="255">1</td>
</tr>
<tr>
<td width="338">Time</td>
<td width="255">0 ~99h59m</td>
</tr>
<tr>
<td width="338">Nitrogen Flow</td>
<td width="255">0 ~12L/m</td>
</tr>
<tr>
<td width="338">Needles Length</td>
<td width="255">150mm</td>
</tr>
<tr>
<td width="338">Column</td>
<td width="255">280</td>
</tr>
<tr>
<td width="338">Gas Pressure</td>
<td width="255">≤0.2MPa</td>
</tr>
<tr>
<td width="338">Power</td>
<td width="255">400W</td>
</tr>
<tr>
<td width="338">Dimension(mm)(L×W×H)</td>
<td width="255">220×290×540</td>
</tr>
<tr>
<td width="338">Insert Blocks</td>
<td width="255">Block Form</td>
</tr>
</tbody>
</table>
<p><strong>Insert Block:</strong><strong> </strong></p>
<p><strong> </strong></p>
<table width="741">
<tbody>
<tr class="firstRow">
<td width="82"><strong>Type</strong></td>
<td width="109"><strong>Specification</strong></td>
<td width="102"><strong>Tube diameter</strong></td>
<td width="129"><strong>Bottom Shape</strong></td>
<td width="170"><strong>Dimension (mm)</strong></td>
</tr>
<tr>
<td width="82">K1</td>
<td width="109">ȼ10mm×12</td>
<td width="102">10.5</td>
<td width="129">Round</td>
<td width="170">153×96.5×50</td>
</tr>
<tr>
<td width="82">K2</td>
<td width="109">ȼ12mm×12</td>
<td width="102">12.5</td>
<td width="129">Round</td>
<td width="170">153×96.5×50</td>
</tr>
<tr>
<td width="82">K3</td>
<td width="109">ȼ13mm×12</td>
<td width="102">13.5</td>
<td width="129">Round</td>
<td width="170">153×96.5×50</td>
</tr>
<tr>
<td width="82">K4</td>
<td width="109">ȼ15mm×12</td>
<td width="102">15.5</td>
<td width="129">Round</td>
<td width="170">153×96.5×50</td>
</tr>
<tr>
<td width="82">K5</td>
<td width="109">ȼ16mm×12</td>
<td width="102">16.5</td>
<td width="129">Round</td>
<td width="170">153×96.5×50</td>
</tr>
<tr>
<td width="82">K6</td>
<td width="109">ȼ19mm×12</td>
<td width="102">19.5</td>
<td width="129">Round</td>
<td width="170">153×96.5×50</td>
</tr>
<tr>
<td width="82">K7</td>
<td width="109">ȼ20mm×12</td>
<td width="102">20.5</td>
<td width="129">Round</td>
<td width="170">153×96.5×50</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>DC150-1A 96-hole Sample Concentrator</title>
		<link>https://eceratrading.com/product/dc150-1a-96-hole-sample-concentrator/</link>
		
		<dc:creator><![CDATA[jose]]></dc:creator>
		<pubDate>Thu, 29 Apr 2021 19:59:00 +0000</pubDate>
				<guid isPermaLink="false">https://eceratrading.com/?post_type=product&#038;p=2862</guid>

					<description><![CDATA[DC150-1A is a high-precision control instrument that combines microcomputer and PID. Working principle: the nitrogen can be blowed onto the surface of the heated samples and then set the heating temperature to achieve rapid concentration of a large number of samples.]]></description>
										<content:encoded><![CDATA[<p><strong>Product Features:</strong></p>
<p>1. Blowing each sample independently, not cause cross-contamination</p>
<p>2. The gas flow can be adjusted</p>
<p>3. Each blow needle can be controlled</p>
<p>4. The gas needle corresponds vertically to the hole, which is intuitive and convenient to adjust.</p>
<p>5. High temperature accuracy, wide temperature range and convenient temperature calibration</p>
<p>6. Protection device, accurate positioning, safe use</p>
<p><strong>The Basic Parameters:</strong></p>
<table width="744">
<tbody>
<tr class="firstRow">
<td width="300"><strong>                 Type</strong></p>
<p><strong>Parameter</strong></td>
<td width="295"><strong>DC150-1A (96-hole)</strong></td>
</tr>
<tr>
<td width="300">Temp. Range</td>
<td valign="top" width="295">R.T+5℃~150℃</td>
</tr>
<tr>
<td width="300">Heating Time</td>
<td valign="top" width="295">≤30min (20℃ to 150℃)</td>
</tr>
<tr>
<td width="300">Temperature   Control Discrepancy@40℃</td>
<td width="295">≤±0.3℃</td>
</tr>
<tr>
<td width="300">Temperature   Control Discrepancy@100℃</td>
<td width="295">≤±0.5℃</td>
</tr>
<tr>
<td width="300">Temperature   Control Discrepancy@120℃</td>
<td width="295">≤±1℃</td>
</tr>
<tr>
<td width="300">Quantity</td>
<td valign="top" width="295">1</td>
</tr>
<tr>
<td width="300">Time</td>
<td valign="top" width="295">0~99h59m</td>
</tr>
<tr>
<td width="300">Nitrogen Flow</td>
<td valign="top" width="295">0~10L/m</td>
</tr>
<tr>
<td width="300">Pressure</td>
<td valign="top" width="295">≤0.5MPa</td>
</tr>
<tr>
<td width="300">Power</td>
<td valign="top" width="295">400W</td>
</tr>
<tr>
<td width="300">Dimension(L×W×H) (mm)</td>
<td valign="top" width="295">220×290×540mm</td>
</tr>
<tr>
<td width="300">Insert Blocks</td>
<td valign="top" width="295">Block Form</td>
</tr>
</tbody>
</table>
<p><strong> </strong></p>
<p><strong>Insert Block:</strong></p>
<table width="719">
<tbody>
<tr class="firstRow">
<td width="83"><strong>Type</strong></td>
<td width="180"><strong>Tube Diameter</strong></td>
<td width="160"><strong>Quantity</strong></td>
<td width="153"><strong>Dimension</strong> (<strong>mm)</strong></td>
</tr>
<tr>
<td width="83">D17</td>
<td width="180">0.2ml Centrifuge tube</td>
<td width="160">96</td>
<td width="153">153×96.5×33.5</td>
</tr>
<tr>
<td width="83">D18</td>
<td width="180">Flat</td>
<td width="160">96-hole Elisa Plate</td>
<td width="153">153×96.5×22.5</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>DC150-2 Sample Concentrator</title>
		<link>https://eceratrading.com/product/dc150-2-sample-concentrator/</link>
		
		<dc:creator><![CDATA[jose]]></dc:creator>
		<pubDate>Thu, 29 Apr 2021 15:57:36 +0000</pubDate>
				<guid isPermaLink="false">https://eceratrading.com/?post_type=product&#038;p=2843</guid>

					<description><![CDATA[DC150-2 is a high-precision control instrument that combines microcomputer and PID. Working principle: the nitrogen can be blowed onto the surface of the heated samples and then set the heating temperature to achieve rapid concentration of a large number of samples.]]></description>
										<content:encoded><![CDATA[<p><strong>Product Features:</strong></p>
<p>1. Blowing each sample independently, not cause cross-contamination</p>
<p>2. The gas flow can be adjusted</p>
<p>3. Each blow needle can be controlled</p>
<p>4. The gas needle corresponds vertically to the hole position, which is intuitive and convenient to adjust.</p>
<p>5. High temperature accuracy, wide temperature range and convenient temperature calibration</p>
<p>6. Protection device, accurate positioning, safe use</p>
<p>&nbsp;</p>
<p><strong>The Basic Parameters:</strong></p>
<table width="744">
<tbody>
<tr class="firstRow">
<td width="291"><strong>               Type</strong></p>
<p><strong>Parameter</strong></td>
<td width="100"><strong>DC150-1</strong></td>
<td width="153"><strong>DC150-2</strong></td>
</tr>
<tr>
<td width="291">Temp. Range</td>
<td colspan="2" width="305">R.T.+5℃—150℃</td>
</tr>
<tr>
<td width="291">Heating Time</td>
<td colspan="2" width="305">≤30min (20℃ to150℃)</td>
</tr>
<tr>
<td width="291">Temperature   Control Discrepancy@40℃</td>
<td colspan="2" width="305">≤±0.3℃</td>
</tr>
<tr>
<td width="291">Temperature   Control Discrepancy@100℃</td>
<td colspan="2" width="305">≤±0.5℃</td>
</tr>
<tr>
<td width="291">Temperature   Control Discrepancy@120℃</td>
<td colspan="2" width="305">≤±1℃</td>
</tr>
<tr>
<td width="291">Quantity</td>
<td width="100">1</td>
<td width="153">2</td>
</tr>
<tr>
<td width="291">Time</td>
<td colspan="2" width="305">0-99h59m</td>
</tr>
<tr>
<td width="291">Nitrogen Flow</td>
<td colspan="2" width="305">0—10L/m</td>
</tr>
<tr>
<td width="291">Pressure</td>
<td colspan="2" width="305">≤0.5MPa</td>
</tr>
<tr>
<td width="291">Power</td>
<td width="100">200W</td>
<td width="153">400W</td>
</tr>
<tr>
<td width="291">Dimension(L×W×H) (mm)</td>
<td colspan="2" width="305">220×290×540</td>
</tr>
<tr>
<td width="291">Insert Blocks</td>
<td colspan="2" width="305">Block Form</td>
</tr>
</tbody>
</table>
<p><strong> </strong></p>
<p><strong>Insert Block:</strong><strong> </strong></p>
<table width="744">
<tbody>
<tr class="firstRow">
<td valign="top" width="107"><strong>Type</strong></td>
<td valign="top" width="203"><strong>Tube Diameter</strong></td>
<td valign="top" width="102"><strong>Quantity</strong></td>
<td valign="top" width="183"><strong>Dimension</strong> (<strong>mm)</strong></td>
</tr>
<tr>
<td valign="top" width="107">D1A</td>
<td valign="top" width="203">6 mm</td>
<td valign="top" width="102">12</td>
<td valign="top" width="183">96.5×76.5×50</td>
</tr>
<tr>
<td valign="top" width="107">D2A</td>
<td valign="top" width="203">7 mm</td>
<td valign="top" width="102">12</td>
<td valign="top" width="183">96.5×76.5×50</td>
</tr>
<tr>
<td valign="top" width="107">D3A</td>
<td valign="top" width="203">10 mm</td>
<td valign="top" width="102">12</td>
<td valign="top" width="183">96.5×76.5×50</td>
</tr>
<tr>
<td valign="top" width="107">D4A</td>
<td valign="top" width="203">12 mm</td>
<td valign="top" width="102">12</td>
<td valign="top" width="183">96.5×76.5×50</td>
</tr>
<tr>
<td valign="top" width="107">D5A</td>
<td valign="top" width="203">13 mm</td>
<td valign="top" width="102">12</td>
<td valign="top" width="183">96.5×76.5×50</td>
</tr>
<tr>
<td valign="top" width="107">D6</td>
<td valign="top" width="203">15 mm</td>
<td valign="top" width="102">12</td>
<td valign="top" width="183">96.5×76.5×50</td>
</tr>
<tr>
<td valign="top" width="107">D7</td>
<td valign="top" width="203">16 mm</td>
<td valign="top" width="102">12</td>
<td valign="top" width="183">96.5×76.5×50</td>
</tr>
<tr>
<td valign="top" width="107">D8</td>
<td valign="top" width="203">19 mm</td>
<td valign="top" width="102">12</td>
<td valign="top" width="183">96.5×76.5×50</td>
</tr>
<tr>
<td valign="top" width="107">D9</td>
<td valign="top" width="203">20 mm</td>
<td valign="top" width="102">12</td>
<td valign="top" width="183">96.5×76.5×50</td>
</tr>
<tr>
<td valign="top" width="107">D10</td>
<td valign="top" width="203">26 mm</td>
<td valign="top" width="102">8</td>
<td valign="top" width="183">96.5×76.5×50</td>
</tr>
<tr>
<td valign="top" width="107">D11</td>
<td valign="top" width="203">28 mm</td>
<td valign="top" width="102">6</td>
<td valign="top" width="183">96.5×76.5×50</td>
</tr>
<tr>
<td valign="top" width="107">D12</td>
<td valign="top" width="203">40 mm</td>
<td valign="top" width="102">3</td>
<td valign="top" width="183">96.5×76.5×50</td>
</tr>
<tr>
<td valign="top" width="107">D13A</td>
<td valign="top" width="203">0.5   ml Centrifuge tube</td>
<td valign="top" width="102">12</td>
<td valign="top" width="183">96.5×76.5×50</td>
</tr>
<tr>
<td valign="top" width="107">D14A</td>
<td valign="top" width="203">1.5   ml Centrifuge tube</td>
<td valign="top" width="102">12</td>
<td valign="top" width="183">96.5×76.5×50</td>
</tr>
<tr>
<td valign="top" width="107">D15A</td>
<td valign="top" width="203">2.0   ml Centrifuge tube</td>
<td valign="top" width="102">12</td>
<td valign="top" width="183">96.5×76.5×50</td>
</tr>
<tr>
<td valign="top" width="107">D16A</td>
<td valign="top" width="203">0.2ml</td>
<td valign="top" width="102">12</td>
<td valign="top" width="183">96.5×76.5×50</td>
</tr>
<tr>
<td valign="top" width="107">D19</td>
<td colspan="3" width="488">Customized</td>
</tr>
</tbody>
</table>
<p><img decoding="async" src="http://www.yooning.com/upload/image/20181012/15393256399213484.jpg" alt="D1A-D16A(1).jpg" /></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>DC150-1 Sample Concentrator</title>
		<link>https://eceratrading.com/product/dc150-1-sample-concentrator/</link>
		
		<dc:creator><![CDATA[jose]]></dc:creator>
		<pubDate>Thu, 29 Apr 2021 15:37:09 +0000</pubDate>
				<guid isPermaLink="false">https://eceratrading.com/?post_type=product&#038;p=2825</guid>

					<description><![CDATA[DC150-1 is a high-precision control instrument that combines microcomputer and PID. Working principle: the nitrogen can be blowed onto the surface of the heated samples and then set the heating temperature to achieve rapid concentration of a large number of samples.]]></description>
										<content:encoded><![CDATA[<p><strong>Product Features:</strong></p>
<p>1. Blowing each sample independently, not cause cross-contamination</p>
<p>2. The gas flow can be adjusted</p>
<p>3. Each blow needle can be controlled</p>
<p>4. The gas needle corresponds vertically to the hole position, which is intuitive and convenient to adjust.</p>
<p>5. High temperature accuracy, wide temperature range and convenient temperature calibration</p>
<p>6. Protection device, accurate positioning, safe use</p>
<p><strong>The Basic Parameters:</strong></p>
<table width="567">
<tbody>
<tr class="firstRow">
<td width="206"><strong>             Type</strong></p>
<p><strong>Parameter</strong></td>
<td width="192"><strong>DC150-1</strong></td>
<td width="169"><strong>DC150-2</strong></td>
</tr>
<tr>
<td width="206">Temp. Range</td>
<td colspan="2" width="361">R.T.+5℃—150℃</td>
</tr>
<tr>
<td width="206">Heating Time</td>
<td colspan="2" width="361">≤30min （20℃ to 150℃)</td>
</tr>
<tr>
<td width="206">Temperature   Control Discrepancy@40℃</td>
<td colspan="2" width="361">±0.3℃</td>
</tr>
<tr>
<td width="206">Temperature   Control Discrepancy@100℃</td>
<td colspan="2" width="361">±0.5℃</td>
</tr>
<tr>
<td width="206">Temperature   Control Discrepancy@120℃</td>
<td colspan="2" width="361">±1℃</td>
</tr>
<tr>
<td width="206">Quantity</td>
<td width="192">1</td>
<td width="169">2</td>
</tr>
<tr>
<td width="206">Time</td>
<td colspan="2" width="361">0-99h59m</td>
</tr>
<tr>
<td width="206">Nitrogen Flow</td>
<td colspan="2" width="361">0—10L/m</td>
</tr>
<tr>
<td width="206">Pressure</td>
<td colspan="2" width="361">≤0.5MPa</td>
</tr>
<tr>
<td width="206">Power</td>
<td width="192">200W</td>
<td width="169">400W</td>
</tr>
<tr>
<td width="206">Dimension(L×W×H) (mm)</td>
<td colspan="2" width="361">220×290×540</td>
</tr>
<tr>
<td width="206">Insert Blocks</td>
<td colspan="2" width="361">Block Form</td>
</tr>
</tbody>
</table>
<p><strong>Insert Block:</strong><strong> </strong></p>
<table width="577">
<tbody>
<tr class="firstRow">
<td class="selectTdClass" valign="top" width="104"><strong>Type</strong></td>
<td class="selectTdClass" valign="top" width="187"><strong>Tube Diameter</strong></td>
<td class="selectTdClass" valign="top" width="109"><strong>Quantity</strong></td>
<td class="selectTdClass" valign="top" width="178"><strong>Dimension</strong> (<strong>mm)</strong></td>
</tr>
<tr>
<td class="selectTdClass" width="104">D1A</td>
<td class="selectTdClass" valign="top" width="187">6 mm</td>
<td class="selectTdClass" valign="top" width="109">12</td>
<td class="selectTdClass" valign="top" width="178">96.5×76.5×50</td>
</tr>
<tr>
<td class="selectTdClass" width="104">D2A</td>
<td class="selectTdClass" valign="top" width="187">7 mm</td>
<td class="selectTdClass" valign="top" width="109">12</td>
<td class="selectTdClass" valign="top" width="178">96.5×76.5×50</td>
</tr>
<tr>
<td class="selectTdClass" width="104">D3A</td>
<td class="selectTdClass" valign="top" width="187">10 mm</td>
<td class="selectTdClass" valign="top" width="109">12</td>
<td class="selectTdClass" valign="top" width="178">96.5×76.5×50</td>
</tr>
<tr>
<td class="selectTdClass" width="104">D4A</td>
<td class="selectTdClass" valign="top" width="187">12 mm</td>
<td class="selectTdClass" valign="top" width="109">12</td>
<td class="selectTdClass" valign="top" width="178">96.5×76.5×50</td>
</tr>
<tr>
<td class="selectTdClass" width="104">D5A</td>
<td class="selectTdClass" valign="top" width="187">13 mm</td>
<td class="selectTdClass" valign="top" width="109">12</td>
<td class="selectTdClass" valign="top" width="178">96.5×76.5×50</td>
</tr>
<tr>
<td class="selectTdClass" width="104">D6</td>
<td class="selectTdClass" valign="top" width="187">15 mm</td>
<td class="selectTdClass" valign="top" width="109">12</td>
<td class="selectTdClass" valign="top" width="178">96.5×76.5×50</td>
</tr>
<tr>
<td class="selectTdClass" width="104">D7</td>
<td class="selectTdClass" valign="top" width="187">16 mm</td>
<td class="selectTdClass" valign="top" width="109">12</td>
<td class="selectTdClass" valign="top" width="178">96.5×76.5×50</td>
</tr>
<tr>
<td class="selectTdClass" width="104">D8</td>
<td class="selectTdClass" valign="top" width="187">19 mm</td>
<td class="selectTdClass" valign="top" width="109">12</td>
<td class="selectTdClass" valign="top" width="178">96.5×76.5×50</td>
</tr>
<tr>
<td class="selectTdClass" width="104">D9</td>
<td class="selectTdClass" valign="top" width="187">20 mm</td>
<td class="selectTdClass" valign="top" width="109">12</td>
<td class="selectTdClass" valign="top" width="178">96.5×76.5×50</td>
</tr>
<tr>
<td class="selectTdClass" width="104">D10</td>
<td class="selectTdClass" valign="top" width="187">26 mm</td>
<td class="selectTdClass" valign="top" width="109">8</td>
<td class="selectTdClass" valign="top" width="178">96.5×76.5×50</td>
</tr>
<tr>
<td class="selectTdClass" width="104">D11</td>
<td class="selectTdClass" valign="top" width="187">28 mm</td>
<td class="selectTdClass" valign="top" width="109">6</td>
<td class="selectTdClass" valign="top" width="178">96.5×76.5×50</td>
</tr>
<tr>
<td class="selectTdClass" width="104">D12</td>
<td class="selectTdClass" valign="top" width="187">40 mm</td>
<td class="selectTdClass" valign="top" width="109">3</td>
<td class="selectTdClass" valign="top" width="178">96.5×76.5×50</td>
</tr>
<tr>
<td class="selectTdClass" width="104">D13A</td>
<td class="selectTdClass" valign="top" width="187">0.5   ml Centrifuge tube</td>
<td class="selectTdClass" valign="top" width="109">12</td>
<td class="selectTdClass" valign="top" width="178">96.5×76.5×50</td>
</tr>
<tr>
<td class="selectTdClass" width="104">D14A</td>
<td class="selectTdClass" valign="top" width="187">1.5   ml Centrifuge tube</td>
<td class="selectTdClass" valign="top" width="109">12</td>
<td class="selectTdClass" valign="top" width="178">96.5×76.5×50</td>
</tr>
<tr>
<td class="selectTdClass" width="104">D15A</td>
<td class="selectTdClass" valign="top" width="187">2.0   ml Centrifuge tube</td>
<td class="selectTdClass" valign="top" width="109">12</td>
<td class="selectTdClass" valign="top" width="178">96.5×76.5×50</td>
</tr>
<tr>
<td class="selectTdClass" width="104">D16A</td>
<td class="selectTdClass" valign="top" width="187">0.2ml</td>
<td class="selectTdClass" valign="top" width="109">12</td>
<td class="selectTdClass" valign="top" width="178">96.5×76.5×50</td>
</tr>
<tr>
<td class="selectTdClass" width="104">D19</td>
<td class="selectTdClass" colspan="3" width="474">Customized</td>
</tr>
</tbody>
</table>
<p><img fetchpriority="high" decoding="async" title="D1A-D16A(1).jpg" src="http://www.yooning.com/upload/image/20181012/15393256399213484.jpg" alt="D1A-D16A(1).jpg" width="640" height="464" /></p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
